Construction

Core : Polyamide

Reinforcement : One or more braids of aramid fiber with anti-static polymeric layer

Cover : Polyurethane, Blue Colour, pin pricked

Application

High pressure Airless paint spray systems for 245 to 350 bar. Suitable for applications requiring chemical resistance to solvents and aggressive fluids

img Temperature Range : Continuous: -40°C to +100°C Temp. not to exceed +70°C for Air and Water based fluids

 

 

 

 

Item Code

Dash Size DN img

ID

OD

OD

img

WP

img

BP

img

BR/r

img

W

inch mm inch mm psi bar psi bar inch mm

g/m

IDA-

-03 05 3/16 4.8 0.413 10.5 5,000 350 20,000 1,400 2.0 50 95.0
IDA- -04 06 1/4 6.4 0.490 12.4 5,000 350 20,000 1,400 3.0 75

125.0

IDA-

-06 10 3/8 9.5 0.630 16.0 4,350 300 17,400 1,200 4.0 100 194.0
IDA- -08 12 1/2 12.7 0.760 19.3 3,500 245 14,000 980 4.7 120

250.0

 

Construction